Creating a Custom Metric to Check SAPRouter SNC Certificate Expiry

This metric and script checks the SAPRouter SNC certificate expiry and gives an alert depending on how many days left until expiry.

Define SAProuter in Focused Run LMDB

Prerequisite: Make sure you have installed the SAP Host Agent and performed Outside Discovery on the SAPRouter host.

Go to the LMDB of you Focused Run system, then go to Single Customer Network:

Switch Namespace and go to “Technical Systems” and choose “Unspecific Standalone Application System” from the drop-down, then hit Create.

Enter:

Enter the Extended SID:

Add Software Component Version:

Search on the software, and then select the correct release, then Add. E.g.:

Save

Add Installation Path and Required LMDB Attributes. NOTE: Find out the relevant software installation path of the SAPRouter on the server.

Perform Simple System Integration

Configure Script and Custom SAPHostCtrl Operation

Prerequisite: The script requires the SAPRouter SNC Certificate to be properly installed, and the PSE credentials in the cred_v2 file for the account that runs the SAPRouter service.

A script is scheduled to run daily as the same user that runs the SAPRouter service. The script reads the expiry date of the from the PSE and writes it to a file in JSON format so that the FRUN metric can read and interpret it. The script by default has SAPRouter home directory as /usr/sap/saprouter or <drive>:\usr\sap\saprouter, and it can be changed. This will be denoted as <SAPROUTER_HOME>. The PSE file variable can also be changed.

Linux/Unix

Create a new executable file in the SAPRouter home directory and copy the code in Appendix A. Ensure it is owned and executable by the user that runs the SAPRouter service and belongs to group sapsys. E.g.,

chown <saprouter user>:sapsys saprouter_expiry_days.sh
chmod 744 saprouter_expiry_days.sh

In the script, adjust the following variables:

  • SAPROUTER_HOME
  • SECUDIR (The SECUDIR folder is where the PSE file resides)
  • SAPROUTER_USER
  • PSE

Test the Script. Switch to the user that runs the SAPRouter service, then execute the script:

/usr/sap/saprouter/saprouter_expiry_days.sh

Look for file NUMDAYS.json. It should contain e.g.:

{type:integer, name:NumDays, value:136}

Schedule script in the root crontab as follows:

# Run SAProuter SNC Certificate expiry check
00 09 * * * su - <saprouter user> -c /usr/sap/saprouter/saprouter_expiry_days.sh

Windows

Create a batch file (*.bat) in the SAPRouter home directory. In the script, adjust the following variables:

  • SAPROUTER_HOME
  • SECUDIR (The SECUDIR folder is where the PSE file resides)
  • PSE

Test the Script. Logon as the user that runs the SAPRouter service. Right-click on the bat script and “run as Administrator”. Alternatively, if you are not logged as the SAPRouter service account, you can “run-as” the user that runs the SAPRouter service and execute the script that way.

runas /user:<domain or hostname>\<SAPRouter service user> <SAPROUTER_HOME>\saprouter_expiry_days.bat

NOTE: The SAPRouter service user requires “Allow log on locally” user rights.

Look for file NUMDAYS.json. It should contain e.g.:

{type:integer, name:NumDays, value:136}

Schedule the Script. Open a command prompt as administrator. Execute the command:

SCHTASKS /CREATE /RU <DOMAIN>\<saprouter user> /RP <password> /SC DAILY /TN "Run SAPRouter SNC Certificate expiry check" /TR "C:\Windows\System32\cmd.exe /C \"<SAPROUTER_HOME>\saprouter_expiry_days.bat\"" /ST 09:00 /RL HIGHEST

Note: The start time e.g., 09:00 is in 24 hour format. You should see:

Run the new task to test it:

SCHTASKS /RUN /TN "Run SAPRouter SNC Certificate expiry check"

You should see:

Check the timestamp of the file NUMDAYS.json.

Create Custom Operation for saphostctrl

To load these values into Focused Run, a custom operation for saphostctrl needs to be created.

Linux/Unix

As Root: Create the following custom operations conf file:

/usr/sap/hostctrl/exe/operations.d/checksnccert.conf

Enter the following into the conf file:

Command: cat /usr/sap/saprouter/NUMDAYS.json
Description: Check number of days to SNC certificate expiry
ResultConverter: flat
Platform: Unix

Test the custom operation as follows:

/usr/sap/hostctrl/exe/saphostctrl -function ExecuteOperation -name checksnccert

Result should be:

Webmethod returned successfully
Operation ID: 06C635D6863A1EEDB6BC5C819EE199D7

----- Response data ----
description=Check number of days to SNC certificate expiry
{type:integer, name:NumDays, value:169}
exitcode=0

Windows

Create the following custom operations conf file:

C:\Program Files\SAP\hostctrl\exe\operations.d\checksnccert.conf

Enter the following into the conf file:

Command: FOR /F "tokens=* delims=" %x in (<SAPROUTER_HOME>\NUMDAYS.json) DO @echo %x
Description: Check number of days to SNC certificate expiry
ResultConverter: flat
Platform: Windows

In a Command Prompt as Administrator, test the custom operation as follows:

"C:\Program Files\SAP\hostctrl\exe\saphostctrl" -function ExecuteOperation -name checksnccert

Result should be:

Webmethod returned successfully
Operation ID: 00155D657F901EEDBCF9E32BC564F964

----- Response data ----
description=Check number of days to SNC certificate expiry
{type:integer, name:NumDays, value:360}
exitcode=0

Create Custom Alert in Focused Run

Create a new monitoring template for SAPRouter here:

Enter into Expert Mode. Create a new Alert with the following settings:

NOTE: If the tick box “Do not Group Individual Occurrences” is ticked, it will alert at each data collection regardless of its previous rating, and not only at a change of rating.

Create Custom Metric In Focused Run

Create a new Metric with the following settings:

Data Collection

All parameters of the Data Collector which are fixed should have the “Configure” box unticked, and the common parameters pre-filled with the correct values.

The “Custom Operation” parameter is the saphostctrl operation “checksnccert” created earlier. The “Metric Name” parameter is the name of the metric in the JSON output file produced by the script, which is “NumDays”.

Usage

Threshold

The threshold picks up the integer as returned by the script; if it falls to below or equals 10 days, then raise a yellow alert, if below or equals 5 days, then raise a red alert. Choose whatever threshold values suit you.

Assignment

Assign the Metric to the Alert:

Activate the Alert

Apply SAPRouter Template and Check Monitoring

TIP: Initially set the collection interval to 5 minutes and apply template to see whether it is collecting data. Then you can set the collection interval back to daily.

You should see this in the Monitoring Application:

Appendix A: saprouter_expiry_days.sh

#!/bin/bash
# Outputs the expiry date of the SNC Certificate and calculates the number of days
# If the number of days falls below threshold, it sends an alert
# Written by Tony Swietochowski

SAPROUTER_USER=saprouter
SAPROUTER_HOME=/usr/sap/saprouter
SECUDIR=$SAPROUTER_HOME/sec
PSE=local.pse
HOSTNAME=$(hostname -f)

# Check  for saprouter user
[[ ! "$USER"=="$SAPROUTER_USER" ]] && echo "This script must be run using the $SAPROUTER_USER user. Exiting." && exit 1

EXPIRYDATE=$(${SAPROUTER_HOME}/sapgenpse get_my_name -p $PSE -n validity 2>&1 | grep NotAfter | awk -F\( '{print$2}' | cut -c -6)
NUMDAYS=$(echo $(( ($(echo $(date --date="$EXPIRYDATE" +%s) - $(date -d $(date +%y%m%d) +%s)) )/86400 )))
# Above method based on https://stackoverflow.com/questions/4946785/how-to-find-the-difference-in-days-between-two-dates

echo $NUMDAYS > $SAPROUTER_HOME/NUMDAYS
echo \{type:integer, name:NumDays, value:$NUMDAYS\} > $SAPROUTER_HOME/NUMDAYS.json

Appendix B: saprouter_expiry_days.bat

@echo off

REM Outputs the expiry date of the SNC Certificate and calculates the number of days
REM If the number of days falls below threshold, it sends an alert
REM Written by Tony Swietochowski

set SAPROUTER_HOME=D:\usr\sap\saprouter
set SECUDIR=%SAPROUTER_HOME%\sec
set SNC_LIB=%SECUDIR%\sapcrypto.dll
set PSE=local.pse

for /f "tokens=2 delims=\" %%i in ('whoami') do set THISUSER=%%i
FOR /F "tokens=* USEBACKQ" %%F IN (`hostname`) DO (SET HOSTNAME=%%F)

chdir /d %SAPROUTER_HOME%

for /f "tokens=2 delims=(" %%a in ('%SAPROUTER_HOME%\sapgenpse.exe get_my_name -p %PSE% -n validity ^2^>^&^1 ^| findstr /l "NotAfter"') do set DATESTRING=(%%a

set expiry_year=20%DATESTRING:~1,2%
set expiry_month=%DATESTRING:~3,2%
set expiry_day=%DATESTRING:~5,2%

set current_year=%date:~-4%
set current_month=%date:~4,2%
set current_day=%date:~7,2%

set "from=%current_month%-%current_day%-%current_year%"
set "to=%expiry_month%-%expiry_day%-%expiry_year%"
echo Wscript.Echo DateDiff("d", "%from%", "%to%") > %TEMP%\tmp.vbs

for /f %%a in ('cscript /nologo %TEMP%\tmp.vbs') do set /a "numdays=%%a"

del %TEMP%\tmp.vbs

echo Number of days to SAPRouter certificate expiry: %numdays% > %SAPROUTER_HOME%\NUMDAYS.log
echo {type:integer, name:NumDays, value:%numdays%} > %SAPROUTER_HOME%\NUMDAYS.json

Creating a Custom Metric to Check if a Linux Filesystem is Mounted…

Some filesystems are critical to a business, such as those used in interfaces. This custom metric group will alert if a filesystem is not mounted.

Create the Bash Script to Check the Filesystem Status

Firstly, we need to create a bash script that takes the filesystem as its input argument and then checks its status. Create the following script called /sbin/checkfilesystemmounted.sh (owner is root, permissions 755). You may put this script somewhere else if you prefer, but be sure to refer to the correct location later on in this post.

#!/bin/bash
findmnt $1 >/dev/null && echo \{type:integer, name:FileSystemMounted, value:1\} || echo \{type:integer, name:FileSystemMounted, value:0\}

The findmnt command returns the mount details if the filesystem is mounted. The filesystem is passed as a script argument in variable $1. If the filesystem is mounted, the script returns integer 1. If the filesystem is not mounted, the script returns integer 0. For example, to check your desired filesystem, execute it like this as root:

/sbin/checkfilesystemmounted.sh /the/filesystem/you/want/to/check

The output will be in JSON format. If the filesystem is mounted, the value will be 1, as follows:

{type:integer, name:FileSystemMounted, value:1}

The name:FileSystemMounted is the name of the value to be picked up by saphostctrl, as described next.

Create the Custom Operation for saphostctrl

To load these values into Focused Run, we create a custom operation for saphostctrl. Create the following custom operations conf file:

/usr/sap/hostctrl/exe/operations.d/checkfilesystemmounted.conf

This contains:

Command: /sbin/checkfilesystemmounted.sh $[FILESYSTEM]
Workdir: /home/sapadm
Description: Check if filesystem is mounted
ResultConverter: flat
Platform: Unix

To test the custom operation, execute the following command:

/usr/sap/hostctrl/exe/saphostctrl -function ExecuteOperation -name checkfilesystemmounted FILESYSTEM=/the/filesystem/you/want/to/check

The result should be as per the following example:

Webmethod returned successfully
Operation ID: 0A02C69098121EDDA68C041B50FE858D

----- Response data ----
description=Check if filesystem is mounted
{type:integer, name:FileSystemMounted, value:1}
exitcode=0

Create the Custom Alert in SAP Focused Run

In Focused Run, we create an alert in a Linux host monitoring template. For example, the alert name is “Interface Filesystem not Mounted”. The Alert should be in Category “Exceptions” and the Severity is up to you. In this case it is 9.

Create the Custom Metric Group in SAP Focused Run

Next, we create the custom Metric Group . A Metric Group allows variants to be created, and each variant corresponds to a filesystem you wish to monitor.

Overview Tab:
  • Name: “Interface Filesystem not Mounted”
  • Category: Exceptions
  • Class: Metric Group
  • Data Type: Integer
  • Technical Name: INTERFACE_FILESYSTEM_NOT_MOUNTED
Data Collection Tab:
  • Data Collector Type: Diagnostic Agent (push)
  • Data Collector Name: OS: ExecuteOperation
  • Collection Interval: 5 Minutes (depending on the criticality)
  • CUSTOM_OPERATION_NAME: checkfileystemmounted – This corresponds to the custom operation for saphostctrl created earlier
  • METRIC_NAME: FileSystemMounted – This corresponds to the name of the metric in the JSON output by the bash script
  • RETURNFORMAT: JSON – This is the output format of the bash script
Usage Tab:
Threshold Tab:

As the script returns a numeric value 0 if the filesystem is not mounted, then the threshold will alert if the value is 0.

Assignment Tab

Assign to the custom alert created earlier.

Add Variants

The variable passed to the saphostctrl operation is “FILESYSTEM”. We can add the rest of the filesystems as individual variants. The format for the operation parameters is as follows:

FILESYSTEM:/the/filesystem/you/want/to/check

For example:

You can enter as many filesystems as you like as separate variants.

Activate Alert

Go to the “Metrics, Events, Alerts Hierarchy” tab, and activate System Monitoring.

Testing the Metric

In a non-Production environment, try to unmount a filesystem, and at most 5 minutes later, there should be an alert produced.

Custom metric for web dispatcher URL monitoring…

When you are using a web dispatcher, you want to check that the main URL is available. You can achieve this via URL monitoring in health monitoring (see blog).

In some cases you want to integrate this vital start URL into system monitoring, since that is your main central tool.

You can create a custom monitoring metric to measure and act on this.

In the use case below we will setup URL monitoring for web dispatcher for SAP Netweaver Gateway serving FIORI pages.

Creation of the custom metric for web dispatcher URL monitoring.

Create a custom metric following the steps in this blog. The template to be adjusted is the technical system SAP Web Dispatcher template.

Don’t forget to tick it on for monitoring otherwise it is not active.

In expert mode create a custom metric.

Create technical name Z_WEBDISPATCHER_URL_AVAILABILITY:

In the data collection:

Data to enter: RFC on diagnostics agent (push). Select SRSM Ping Http Unsp. Select the HTTPS protocol and setup the URL to monitor: /sap/bc/ui2/flp?sap-client=xxx&sap-language=EN. This is the main FIORI start URL. The port number is taken from the LMDB settings of the web dispatcher: $SAP_WebDispatcherIPServicePort->SAP_IPServicePort.PortNumber$.

Define the threshold for alerting:

We take here three measurements. If we don’t then with a single glitch in the network an alert will be triggered.

And assign the metric to the system message alert group:

Custom metric to detect if there are no free work processes…

From availability perspective, you want to detect as quickly as possible if you don’t have any free work processes left.

You can create a custom monitoring metric to measure and act on this.

Creation of the custom metric for no free work processes

Create a custom metric following the steps in this blog. The template to be adjusted is the technical instance SAP ABAP 7.10 and higher template.

Don’t forget to tick it on for monitoring otherwise it is not active.

In expert mode create a custom metric.

Create technical name Z_NO_FREE:

In the data collection:

Data to enter: RFC on diagnostics agent (push). Select ABAP System Log Stats. Filter on message number QoG with text *NOWP*.. For more information on system log messages, read this blog.

Define the threshold for alerting:

And assign the metric to the ABAP Resource Shortage alert group:

Custom metric to detect if hardware ID is missing…

From availability perspective, you want to detect as quickly as possible if you are suffering from missing hardware ID.

You can create a custom monitoring metric to measure and act on this.

Creation of the custom metric for missing hardware ID

Create a custom metric following the steps in this blog. The template to be adjusted is the technical instance SAP ABAP 7.10 and higher template.

Don’t forget to tick it on for monitoring otherwise it is not active.

In expert mode create a custom metric.

Create technical name Z_METRIC_MSG_SRV_HW_ID_MISSING:

In the data collection:

Data to enter: RFC on diagnostics agent (push). Select ABAP System Log Stats. Filter on message number Q16. This indicates missing hardware ID. For more information on system log messages, read this blog.

Define the threshold for alerting:

And assign the metric to the ABAP Instance not available alert group, create a custom alert group:

Msg Server hardware ID missingChecks for Syslog message Q16. Threshold Red for 1.

Custom metric to check OS signal…

In some cases the OS system will give critical signals to the SAP system that are visible in the ABAP system log. An example is the signal 11.

When this happens, the system is in trouble and you as admin need to check fast to see what is going on to stop the system from full collapse, crash or very poor performance.

You can create a custom monitoring metric to measure and act on this.

Creation of the custom metric for OS signal detection

Create a custom metric following the steps in this blog. The template to be adjusted is the technical instance SAP ABAP 7.10 and higher template.

Don’t forget to tick it on for monitoring otherwise it is not active.

In expert mode create a custom metric.

Create technical name Z_METRIC_OS_SIGNAL_RECEIVED:

In the data collection:

Data to enter: RFC on diagnostics agent (push). Select ABAP System Log Stats. Filter on MSG_ID QoE. This captures severe errors for OS signals.

Define the threshold for alerting:

And assign the metric to the system message alert group:

Detecting long running DIA process…

In some exceptional cases you can have a DIA process that runs for a long time without action and still occupies the resources.

You can create a custom monitoring metric to measure and act on this.

Creation of the custom metric for detecting long running DIA processes

Create a custom metric following the steps in this blog. The template to be adjusted is the technical system SAP ABAP 7.10 and higher template.

Don’t forget to tick it on for monitoring otherwise it is not active.

In expert mode create a custom metric.

Create technical name Z_METRIC_LONGRUN_DIA_WP_36HRS:

Now setup the definition for the data collection:

It is using the Push.

And set the usage:

Last but not least: you need to set the alerting threshold:

The alert is raised if a single DIA work process is running longer than 36 hours.

Save the custom metric and make sure the template reassignment is done to activate the custom metric for your systems.

ABAP system monitoring detecting PRIV modes…

When you system has too many PRIV modes, it is about to fall over. This situation must be detected and acted upon.

You can create a custom monitoring metric to measure and act on this.

Creation of the custom metric for detecting PRIV modes

Create a custom metric following the steps in this blog. The template to be adjusted is the technical system SAP ABAP 7.10 and higher template.

Don’t forget to tick it on for monitoring otherwise it is not active.

In expert mode create a custom metric.

Create technical name Z_METRIC_DIA_WP_PRIV:

Now setup the definition for the data collection:

This will collect the PRIV dialog processes in percentage.

Mark the custom metric as relevant for monitoring:

And set the usage:

Last but not least: you need to set the alerting threshold:

Save the custom metric and make sure the template reassignment is done to activate the custom metric for your systems.

System monitoring custom metric for errors in table locking of TBTCO…

From availability perspective, you want to detect as quickly as possible if you are suffering from locking errors of table TBTCO. TBTCO table is used for printing. If the locking error situation occurs the printing function will fail, and even worse, it can impact the complete SAP ABAP system.

You can create a custom monitoring metric to measure and act on this.

Creation of the custom metric for errors in table locking of TBTCO

Create a custom metric following the steps in this blog. The template to be adjusted is the technical instance SAP ABAP 7.10 and higher template.

Don’t forget to tick it on for monitoring otherwise it is not active.

In expert mode create a custom metric.

Create technical name Z_METRIC_ERR_LOCK_TBTCO:

In the data collection:

Data to enter: RFC on diagnostics agent (push). Select ABAP System Log Stats. Filter on message text *TBTCO*. This captures severe errors for TBTCO like the locking error.

Define the threshold for alerting:

And assign the metric to the ABAP Instance not available alert group:

System monitoring custom metric for message server disconnects…

From availability perspective, you want to detect as quickly as possible if you are suffering from message server disconnects.

You can create a custom monitoring metric to measure and act on this.

Creation of the custom metric for message server disconnects

Create a custom metric following the steps in this blog. The template to be adjusted is the technical instance SAP ABAP 7.10 and higher template.

Don’t forget to tick it on for monitoring otherwise it is not active.

In expert mode create a custom metric.

Create technical name Z_MESSAGE_SERVER_DISCONNECT:

In the data collection:

Data to enter: RFC on diagnostics agent (push). Select ABAP System Log Stats. Filter on message number Q0L, Q0M and Q0N. Any of those indicate message server errors. For more information on system log messages, read this blog.

Define the threshold for alerting:

And assign the metric to the ABAP Instance not available alert group:

Exit mobile version